Cino HB2100 User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
10
Batch Scanning
Thanks to the Batch Scanning function, the scanner is capable of storing all
input data into memory storage. It is an ideal cost-effective solution to fulfill
most inventory applications.
Configure Batch Scanning Options
Before you start to use batch scanning, please enter SETUP then select
Batch Scanningto configure all available options listed below. Moreover,
the “Auto Save” and “Auto Delete” functions will help you to simplify the
routine operation of data collecting.
Input Fields
Besides the field of “Item No.”, three more input fields are available for choice,
including Quantity”, Location and “Timestamp”. By default, both “Item
No.” and “Quantity” fields are enabled. Please note that if you changed the
composition of input fields, all stored data will be DELETED.
Validation
You can set the desired input range of each field. The scanner will do the
validation automatically after the inputs of each field are completed.
Field and Record Delimiters
Both field delimiter and record delimiter can be changed to meet your
application demand.
Transmission Sequence
The transmission sequence of each field can be re-arranged to meet your
needs.
Transmission Interface
The scanner is preset to transmit all stored data through Wi-Fi. Alternatively,
you can transmit the stored data through physical USB interface by changing
the transmission interface to USB COM or USB HID. In this case, a charging
cradle has to be used together with your scanner.
Auto Save
After completing the inputs of each record, the scanner will save the data into
storage automatically then go to next record input immediately. You do not
need to press Save (L Key) to save data. If you still prefer to save data
manually, please disable this Auto Save function.
Auto Delete
The scanner is preset to keep all stored data after data transmission in case it
needs to be retrieved later. You have to delete all records manually. If you
prefer the scanner to perform “Auto Delete” after data transmission, please
enable this function.
Link Control
For power saving, the Radio can be disabled during batch scanning. When
you want to transmit the data via Wi-Fi, the scanner will activate the Radio
and re-connect automatically.
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments