Command Descriptions
2-13
Exit Capture Image Mode
(TS)
Descriptions
Exit Capture Image Mode
Available for A series
Packet Format
Prefix Opcode Status
Length
Parameter(s) LRC Suffix
7Eh
80h 1Ah 01h
00h 00h 00h
<NULL> 9B 7Eh
1 Byte 3 Bytes 1 Byte 2 Bytes
0 Byte 1 Byte 1 Byte
. Host Requirements
If the device successfully received the above command issued by the host, a “Device ACK” will be sent
to the host right after the device performed the action. Otherwise, a “Device NAK” will be sent to host to
issue a command error. However, if the host can not receive any response from the device within the
user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
. LRC
“Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”