Command Descriptions
2-44
Remote Programming
(WF)
Descriptions
Enter or exit the Programming Mode.
Wi-Fi scanner can only perform Remote Control commands when it is not in Programming mode.
Remote Programming (Enter) is used to put scanner into programming mode, so that the
subsequent programming commands will take effect. Please refer to Briefing Chapter (Page 1-2) for
detailed descriptions. Note that in programming mode the scanner can not work until the Remote
Programming (Exit) or Remote Programming Extension (Exit) is sent.
Available for F & L series
Packet Format
Prefix Opcode Status Length
Parameter(s) LRC Suffix
7Eh
80h 90h 06h
00h 00h 01h
See Below Variable
7Eh
1 Byte 3 Bytes 1 Byte 2 Bytes
1 Byte 1 Byte 1 Byte
. Host Requirements
If the device successfully received the above command issued by the host, a “Device ACK” will be sent
to the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to
issue a command error. However, if the host can not receive any response from the device within the
user preset time-out duration, please resend the above command.
. Length
Total size (bytes) of the Parameter(s) field
. LRC
”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”
Parameter(s)
< Table 4-7 > Remote Programming Parameter(s) Field
Parameter / PID / Size Options Descriptions
Remote Programming
PID : <Null>
Size : 00h 01h (1 Byte)
- 00h
- 01h
Exit Remote Programming
Enter Remote Programming
Serial Command
Enter Remote Programming
0x7e 0x80 0x90 0x5c 0x02 0x00 0x00 0x01 0x01 0x16 0x7e
Exit Remote Programming
0x7e 0x80 0x90 0x5c 0x02 0x00 0x00 0x01 0x00 0x17 0x7e
. Notes
0x5C 0x02: the escaped value of 0x06.